No. | Malfunction | Cause | Trouble-shooting |
1 | The level of syrup inside the syrup filter is not full enough or there are many bubbles. | The pressure of syrup entry is continuously lower than 0.01MPa; or Flux is not enough; or pipe resistance is big or blocked; or any leakage of pipe or one-way vlave occurs. | Take respective measures: increase the pressure; or flux; or decrease the resistance; or check and repair the pipes and valves. |
2 | The pump is running without any output of liquid. | There is air existing inside the pump. | Pour relative liquid into the pump to drive the air out. |
3 | The flow of water to the water tank is weak. | Sprayer in the water tank is jammed; or the pressure inside is high; or the vacuum in the deaerator tank is high. | Stop, clean the sprayer; or lower the pressure; or lower the vacuum. |
4 | Pneumatic valve can not be opened or too slowly opened. | The respective solenoid has problem; or the air input or output is not proper. | Check the solenoid valve; or adjust the air input or output proper. |
5 | The syrup tank can not be filled with syrup. | There is air existing inside the pump;or floating-ball liquid level instrument fails; or one way valve fails; or the pump fails. | Drain the air in the pump; or repair the floating-ball liquid level instrument or one-way valve; or proper operation of pump. |
6 | There is water in the CO2 reflux release valve; or one-way valve leakage. | Mis-operation or one-way valve fails. | Proper operation; or dismantle the release valve drain the water and dry it; or check the one-way valve and clean it. |